×
近期发现有不法分子冒充我刊与作者联系,借此进行欺诈等不法行为,请广大作者加以鉴别,如遇诈骗行为,请第一时间与我刊编辑部联系确认(《中国物理C》(英文)编辑部电话:010-88235947,010-88236950),并作报警处理。
本刊再次郑重声明:
(1)本刊官方网址为cpc.ihep.ac.cn和https://iopscience.iop.org/journal/1674-1137
(2)本刊采编系统作者中心是投稿的唯一路径,该系统为ScholarOne远程稿件采编系统,仅在本刊投稿网网址(https://mc03.manuscriptcentral.com/cpc)设有登录入口。本刊不接受其他方式的投稿,如打印稿投稿、E-mail信箱投稿等,若以此种方式接收投稿均为假冒。
(3)所有投稿均需经过严格的同行评议、编辑加工后方可发表,本刊不存在所谓的“编辑部内部征稿”。如果有人以“编辑部内部人员”名义帮助作者发稿,并收取发表费用,均为假冒。
                  
《中国物理C》(英文)编辑部
2024年10月30日

A capacitance servo control plunger for accurate lifetime measurement

Get Citation
WANG Jin-Long, WU Xiao-Guang, HE Chuang-Ye, LI Guang-Sheng, FAN Qi-Wen, DU Ying-Hui, WU Yi-Heng, HU Shi-Peng, ZHENG Yun, LI Cong-Bo, LI Hong-Wei, LIU Jia-Jian, LUO Peng-Wei and YAO Shun-He. A capacitance servo control plunger for accurate lifetime measurement[J]. Chinese Physics C, 2014, 38(3): 036201. doi: 10.1088/1674-1137/38/3/036201
WANG Jin-Long, WU Xiao-Guang, HE Chuang-Ye, LI Guang-Sheng, FAN Qi-Wen, DU Ying-Hui, WU Yi-Heng, HU Shi-Peng, ZHENG Yun, LI Cong-Bo, LI Hong-Wei, LIU Jia-Jian, LUO Peng-Wei and YAO Shun-He. A capacitance servo control plunger for accurate lifetime measurement[J]. Chinese Physics C, 2014, 38(3): 036201.  doi: 10.1088/1674-1137/38/3/036201 shu
Milestone
Received: 2013-01-31
Revised: 1900-01-01
Article Metric

Article Views(1871)
PDF Downloads(182)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

A capacitance servo control plunger for accurate lifetime measurement

    Corresponding author: WANG Jin-Long,
    Corresponding author: WU Xiao-Guang,

Abstract: The recoil distance Doppler shift method has been widely used in the study of nuclear structure to determine the level lifetime and absolute transition probabilities. A capacitance servo control plunger based on this method has been successfully developed by the Nuclear Structure Group of the China Institute of Atomic Energy. Three microscopes were employed to check the parallelism and can therefore guarantee a delicate measurement of the distance between the target and the stopper. This new plunger made a successful performance in the test experiment and the measured lifetime of the 2+→0+ transition in 78Kr is in agreement with the previous value.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return