Studies on High Energy γ Trigger of Lead-Scintillating Fiber Electromagnetic Calorimeter

Get Citation
YANG Zhao-Yu, CHEN Guo-Ming, CHEN Gang, YANG Min, WANG Xiao-Bin, LI Zu-Hao, ZHANG Shao-He, LU Yu-Sheng and CHEN He-Sheng. Studies on High Energy γ Trigger of Lead-Scintillating Fiber Electromagnetic Calorimeter[J]. Chinese Physics C, 2004, 28(10): 1086-1089.
YANG Zhao-Yu, CHEN Guo-Ming, CHEN Gang, YANG Min, WANG Xiao-Bin, LI Zu-Hao, ZHANG Shao-He, LU Yu-Sheng and CHEN He-Sheng. Studies on High Energy γ Trigger of Lead-Scintillating Fiber Electromagnetic Calorimeter[J]. Chinese Physics C, 2004, 28(10): 1086-1089. shu
Milestone
Received: 2004-01-06
Revised: 1900-01-01
Article Metric

Article Views(3047)
PDF Downloads(699)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Studies on High Energy γ Trigger of Lead-Scintillating Fiber Electromagnetic Calorimeter

    Corresponding author: YANG Zhao-Yu,
  • Institute of High Energy Physics,CAS,Beijing 100039,China

Abstract: The high flux of cosmic ray proton forms the main background of γ ray detection experiments using a lead scintillating fiber sandwiched electromagnetic calorimeter. The trigger scheme is studied to efficiently detect high energy γ rays and reject most of the proton events. Efficient cuts are derived from the Monte Carlo analysis of electromagnetic shower shape in the calorimeter. Photons with energy above 10GeV are triggered at the level of 99%. The requirement of proton rate less than 100 Hz is also satisfied. The accuracy of the simulations is testified with the beam test.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return