×
近期发现有不法分子冒充我刊与作者联系,借此进行欺诈等不法行为,请广大作者加以鉴别,如遇诈骗行为,请第一时间与我刊编辑部联系确认(《中国物理C》(英文)编辑部电话:010-88235947,010-88236950),并作报警处理。
本刊再次郑重声明:
(1)本刊官方网址为cpc.ihep.ac.cn和https://iopscience.iop.org/journal/1674-1137
(2)本刊采编系统作者中心是投稿的唯一路径,该系统为ScholarOne远程稿件采编系统,仅在本刊投稿网网址(https://mc03.manuscriptcentral.com/cpc)设有登录入口。本刊不接受其他方式的投稿,如打印稿投稿、E-mail信箱投稿等,若以此种方式接收投稿均为假冒。
(3)所有投稿均需经过严格的同行评议、编辑加工后方可发表,本刊不存在所谓的“编辑部内部征稿”。如果有人以“编辑部内部人员”名义帮助作者发稿,并收取发表费用,均为假冒。
                  
《中国物理C》(英文)编辑部
2024年10月30日

Analysis and Calculation on Electron Bunch Length Measurementby Using CDR

  • Measurement of electron bunch length through its generated coherent diffraction radiation (CDR) via optical autocorrelation is a new non-intercepting frequency domain diagnostics technique developed in accelerator fields recently. In this paper, the CDR emitted by femto-second electron bunches provided by the SINAP linac are analyzed and numerically calculated, experimental designs on CDR generation and bunch length measurement are presented, and the beam splitter affected interferogram is simulated. As a result, broad band continuous and high intensity CDR covering a range from far-infrared to mm-wave region can be obtained by directly using these bunches. CDR energy is mainly concentrated near the beam axis and can be up to several millijoules for Gaussian bunches. We use a far-infrared Michelson interferometer and a Golay detector to measure the autocorrelation interferogram of CDR, considering the interference effects caused by the beam splitter, the electron bunch length can be easily obtained, from which one can derive its electron density distribution.
  • 加载中
  • [1] .LCLS Technical Design Report,SLAC-R2593 LC2414.April,20022.LI Zhi-Hui et al.HEP NP,2003,27(9):831)835 (in Chinese)(李智慧等,高能物理与核物理,2003,27(9):831)835)3.Uesaka U,Ueda T et al.Nucl.Instrum.Methods,1998,A 406:371)3794.Barry W.Proc.of the Workshop on Advanced Beam Instrument ation,KEK,Tsukuba,Japan,April,19915.Kung P,Lihn H,Bocck D et al.Phys.,Rev.,Lett.,1994,73:967)9706.ZHU Jun-Biao et al.HEP NP,2000,24 (2):172)180 (in Chinese)(朱俊彪等.高能物理与核物理,2000,24(2):172)180)7.Shibata Y,Hasebe S,Ishi K et al.Phys.Rev.,1995,E52:6787)67948.Lumpkin A H,Sereno N S,Rule DW.Nucl.Instrum.Methods,2001,A475:470)4759.Settakorn C.Proceedings of the Second Asian Particle Accelerator Conference.Beijing,China,2001.514)51610.Cast ellaoM,VerzilovY,Catani L et al.DIPAC 2001 Proceedings)ES-RF,Grenoble11.Ter Mikaelian M L.High Energy Electromagnet ic Processes in Condensed Media.In:Wiley Intersciencr.New York:Academic Press,1972.377)38912.Feng B,Oyamada M,Hinode F et al.Nucl.Instrum.and Methods,2001,A475:492)49713.Kinura WD,Fiorito R B,Rule D W.Proceeding of the 1999 Part icleAccelerat ion Conference.New York,1999.487)48914.Nodvick J S,Saxon D S.Phys.Rev.,1954,96:180)18415.Lihn H C,Kung P,Set takorn C et al.Phys.Rev.,1996,A53:6413)641816.Settakon C.Generation and Use of Coherent Transit ion Radiat ion fromShort Electron Bunches.PhD Thesis,St anford University,California,1996.113)116
  • 加载中

Get Citation
LIU Ai-Qin, LOU Zheng-Ping, CHEN You-Zhong, ZHOU Wei-Min and Dai Zhi-Min. Analysis and Calculation on Electron Bunch Length Measurementby Using CDR[J]. Chinese Physics C, 2005, 29(5): 517-523.
LIU Ai-Qin, LOU Zheng-Ping, CHEN You-Zhong, ZHOU Wei-Min and Dai Zhi-Min. Analysis and Calculation on Electron Bunch Length Measurementby Using CDR[J]. Chinese Physics C, 2005, 29(5): 517-523. shu
Milestone
Received: 2004-09-29
Revised: 2004-11-27
Article Metric

Article Views(4069)
PDF Downloads(559)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Analysis and Calculation on Electron Bunch Length Measurementby Using CDR

    Corresponding author: LIU Ai-Qin,
  • Shanghai Institute of Applied Physics,Shanghai 201800,China

Abstract: Measurement of electron bunch length through its generated coherent diffraction radiation (CDR) via optical autocorrelation is a new non-intercepting frequency domain diagnostics technique developed in accelerator fields recently. In this paper, the CDR emitted by femto-second electron bunches provided by the SINAP linac are analyzed and numerically calculated, experimental designs on CDR generation and bunch length measurement are presented, and the beam splitter affected interferogram is simulated. As a result, broad band continuous and high intensity CDR covering a range from far-infrared to mm-wave region can be obtained by directly using these bunches. CDR energy is mainly concentrated near the beam axis and can be up to several millijoules for Gaussian bunches. We use a far-infrared Michelson interferometer and a Golay detector to measure the autocorrelation interferogram of CDR, considering the interference effects caused by the beam splitter, the electron bunch length can be easily obtained, from which one can derive its electron density distribution.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return