Nuclear Counter Effect of Silicon Photodiode Used in CsI(Tl) Crystal Calorimeter

  • We investigated the nuclear counter effect of the silicon photodiode mounted on a CsI(Tl) crystal detector due to the leakage of electromagnetic shower through the rear end of the crystal. Using electron beams at IHEP, we have tested its effect on the energy measurement by the CsI(Tl) calorimeter for BESⅢ experiment. The results are found to be in good agreement with that of GEANT simulation and the effect for the BESⅢ calorimeter is negligible.
  • 加载中
  • [1] . Preliminary Design Report of the BES0 Detector InternalDocument, 2003. 119-133(in Chinese)(北京正负电子对撞机重大改造上程BEPC II初步设计BESIII探测器.2003. 119-133)2. Satpathy A, Tamai K, Fukushima M et al. Nuclear CounterE ect of Silicon PIN Photodiode Used in CsI(Tl) CalorimeterN.I.M in Physics Research, 1997, A391: 423-4263. XIA Xiao-Mi, WANG Man, LU Jun-Guang et al. TheStudy of Photodiode Read out for Scintillation CrystalCalorimeter.In: Academy of Nuclear Electronics NuclearDetection Technology ed. Proceedings of the 11th NationalConference on Nuclear Electronics Nuclear DetectionTechnology. 2002. 231-235(in Chinese)(夏小米,王曼,吕军光等.闪烁晶体量能器用硅光一级管读出的研究.见:中国电子学会、中国核学会、核电子学与核探测技术分会编辑.第11届个国核电子学与核探测器学术年会论文集,2002. 231-235)4. CUI Xiang-Zong, LI Jia-Cai et al. HEP NP, 2004, 28(8):870-876(in Chinese)(崔象宗,李家才等.高能物理与核物理,2004, 28(8): 870-876)5. LIU Chun-Xiu. The Monte-Carlo Simulation Study of theBES0 Crystal Calorimeter. In: Institute of High EnergyPhysics, Chinese Academy of Sciences ed. The PostdoctoralStudy Report of Institute of High Energy Physics,Chinese Academy of Sciences. 2003. 1-52(in Chinese)(刘春秀.BES川晶体量能器的蒙特片罗模拟研究.见:中国科学院高能物理研究所(北京)编辑.中国科学院高能物理研究所博士后研究上作报告.2003. 1-52)
  • 加载中

Get Citation
WANG Zhi-Gang, SHAN Li-Min, SHANG Lei, XIE Wen-Jie, QIN Gang, LIU Chun-Xiu, YU Bo-Xiang, DONG Ming-Yi, CAI Xiao, ZHOU Li, XIA Xiao-Mi, LAI Yuan-Fen, WANG Man, Nuclear Counter Effect of Silicon Photodiode Used in CsI(Tl) Crystal Calorimeter[J]. Chinese Physics C, 2006, 30(9): 876-879.
WANG Zhi-Gang, SHAN Li-Min, SHANG Lei, XIE Wen-Jie, QIN Gang, LIU Chun-Xiu, YU Bo-Xiang, DONG Ming-Yi, CAI Xiao, ZHOU Li, XIA Xiao-Mi, LAI Yuan-Fen, WANG Man, Nuclear Counter Effect of Silicon Photodiode Used in CsI(Tl) Crystal Calorimeter[J]. Chinese Physics C, 2006, 30(9): 876-879. shu
Milestone
Received: 2006-01-17
Revised: 2006-02-08
Article Metric

Article Views(3459)
PDF Downloads(685)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Nuclear Counter Effect of Silicon Photodiode Used in CsI(Tl) Crystal Calorimeter

    Corresponding author: WANG Zhi-Gang,
  • Institute of High Energy Physics, CAS, Beijing 100049, China2 Shanxi Normal University, Linfen 041004, China

Abstract: We investigated the nuclear counter effect of the silicon photodiode mounted on a CsI(Tl) crystal detector due to the leakage of electromagnetic shower through the rear end of the crystal. Using electron beams at IHEP, we have tested its effect on the energy measurement by the CsI(Tl) calorimeter for BESⅢ experiment. The results are found to be in good agreement with that of GEANT simulation and the effect for the BESⅢ calorimeter is negligible.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return