Thin Plastic Scintillating Foil for Measuring Pulsed Neutron Flux in High Gamma-Ray Environment

  • A new conception of measuring pulsed neutron flux in high gamma–ray environment with a thin plastic scintillating foil is presented. based on the calculations of the response to neutrons and gamma–rays, a new gamma–insensitive detector for detecting fast rising, transient neutron flux has been developed and preliminarily tested, which comprises a thin plastic scintillating foil of st401 (tPsf) and a photomultiplier tube (or a photodiode). the detector exhibits three distinct properties compared with the conventional ones: (1) high neutron sensitivity, (2) high n/γ discrimination, and (3) flat response in the given neutron energy range.
  • 加载中
  • [1] .  LIU Q Z et al . The Diagnosis Technology of Pulse Radiation Field. Beijing : Science Press , 1994. 1 —702 (in Chinese)(刘庆兆等1 脉冲辐射场诊断技术. 北京:科学出版社, 1994.1—702)2. Ebert P J. UCRL-537243. Kuckuck R W.UCRL-510114. OUYANG Xiao-Ping et al1 CNIC-012141 Beijing :Atomic Energy Press ,1997. NINT-0001 :1 —7 (in Chinese) .(欧阳晓平等. 中国核科技报告1 北京: 原子能出版社,19971NINT-0001 :1 —7)5. OUYANG Xiao-Ping et al1 HEP NP , 2001 ,25 (11) :1100 —1105 (in Chinese)(欧阳晓平等1 高能物理与核物理, 2001 , 25(11) :1100 —1105)6. Kronenberg S. Nucleonics , 1963 ,21 :78 —797. Muga ML ,Bridges J D. Nucl . Instrum. and Methods ,1976 ,134 :143 —1478. Geissel H et al . Nucl . Instrum. and Methods , 1977 , 144 :465 —4689. Ettling K, Witsch W V. Nucl . Instrum. and Methods , 1978 , 148 :299 —30110. Brooks F D , Cilliers W A , Allie M S. Nucl . Instrum. and Methods ,1985 ,A240 :338 —34211. Kanno I ,Nakagome Y. Nucl . Instrum. and Methods , 1986 , A251 :108 —11412. Knoll G F. Radiation Detection and Measurement. John Wiley Sons ,Inc. , 199911 —70013. Beddingfield D H , Menlove H O , Johnson N H. Nucl . Instrum. and Methods , 1999 , A422 :35 —4014. ZHAO Y X et al1 Nucl . Instrum. and Methods , 1995 , A355 :464 —46815. Reeder P L et al. Nucl . Instrum. and Methods , 1999 , A422 :84 —8816. Singkarat S , Garis N S , Grosshog G. Nucl . Instrum. and Methods ,1993 ,A335 : 248 —25117. Singkarat S et al . Nucl . Instrum. and Methods , 1997 ,A384 :463 —47018. Bartle C M, Haight R C. Nucl . Instrum. and Methods , 1999 , A422 :54 —5819. Smith DL , Polk R G,Miller T G. Nucl . Instrum. and Methods , 1968 ,64 :157 —16620. Byrd R C et al . Nucl . Instrum. and Methods , 1992 ,A313 : 457 —46321. Craun RL , Smith DL1 Nucl . Instrum. and Methods , 1970 , 80 :239 —24422. Badhwar GD et al . Nucl . Instrum. and Methods , 1967 , 57 : 116 —12023. Briesmeister Judith F. MCNP —A General Monte Carlo N-ParticleTransport Code : LA-12625-M, Version 4B ,199724. XU C X,HE H L , HE H H et al . Acta. Phys. Sin. (Overseas Edition) , 1999 , 8 : 63 —65
  • 加载中

Get Citation
OUYANG Xiao-Ping, LI Zhen-Fu, WANG Qiu-Shu and HUO Yu-Kun. Thin Plastic Scintillating Foil for Measuring Pulsed Neutron Flux in High Gamma-Ray Environment[J]. Chinese Physics C, 2005, 29(4): 399-403.
OUYANG Xiao-Ping, LI Zhen-Fu, WANG Qiu-Shu and HUO Yu-Kun. Thin Plastic Scintillating Foil for Measuring Pulsed Neutron Flux in High Gamma-Ray Environment[J]. Chinese Physics C, 2005, 29(4): 399-403. shu
Milestone
Received: 2004-08-17
Revised: 1900-01-01
Article Metric

Article Views(4235)
PDF Downloads(627)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Thin Plastic Scintillating Foil for Measuring Pulsed Neutron Flux in High Gamma-Ray Environment

    Corresponding author: OUYANG Xiao-Ping,
  • Northwest Institute of Nuclear Technology,Xi'an 710024,China2 Institute of Modern Physics,Fudan University,Shanghai 200433,China3 Department of nuclear engineering,Tsinghua University,Beijing 100084,China

Abstract: A new conception of measuring pulsed neutron flux in high gamma–ray environment with a thin plastic scintillating foil is presented. based on the calculations of the response to neutrons and gamma–rays, a new gamma–insensitive detector for detecting fast rising, transient neutron flux has been developed and preliminarily tested, which comprises a thin plastic scintillating foil of st401 (tPsf) and a photomultiplier tube (or a photodiode). the detector exhibits three distinct properties compared with the conventional ones: (1) high neutron sensitivity, (2) high n/γ discrimination, and (3) flat response in the given neutron energy range.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return