Study of Radiative Source Positioning by Counting Rate Variations of a Monitor System

  • Standard radiative source are monitored by a system containing several detectors. When a source moved out from the monitored area, the counting rates of the system will be changed, and the position and radiation intensity of the source can be estimated by the counting rates variations.
  • 加载中
  • [1] . LIU S P ,HU G C et al.Acta Phys.Sin.,2001,50:1405(in Chinese)(刘素萍,胡广春等.物理学报,2001,50:1405) 2. KNOLL G F .Radiation Detection and Measurement.America:JION WILEYSONS ,1979.60 3. WANG Ling.Linear Algebra.Beijing:National Defense Industry Press,1996.84(in Chinese). (王玲.线性代数.北京:国防工业出版社,1996.84)4. Fudan University,Qinghua University,Peking University.Atomic Nucle us Physics Experiment Method.Beijing:Atomic Energy Press,1985.11(in Chinese). (复旦大学,清华大学,北京大学.原子核物理实验方法.北京:. 原子能出版社,1985.11)5. WU XueChao,FENG ZhengYong.DP of Nuclear Physics Experiment,Beijing:Atomic Energy Press,1988.184—187(in Chinese)(吴学超,冯正永.核物理实验数据处理方法,北京:原子能出版. 社,1988.184—187)
  • 加载中

Get Citation
CHU Cheng-Sheng, HUANG Rui-Liang, LIU Xiao-Ya, XIONG Zong-Hua, XIANG Yong-Chun and ZHANG Jian-Hua. Study of Radiative Source Positioning by Counting Rate Variations of a Monitor System[J]. Chinese Physics C, 2003, 27(9): 836-840.
CHU Cheng-Sheng, HUANG Rui-Liang, LIU Xiao-Ya, XIONG Zong-Hua, XIANG Yong-Chun and ZHANG Jian-Hua. Study of Radiative Source Positioning by Counting Rate Variations of a Monitor System[J]. Chinese Physics C, 2003, 27(9): 836-840. shu
Milestone
Received: 2003-01-27
Revised: 1900-01-01
Article Metric

Article Views(4419)
PDF Downloads(580)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Study of Radiative Source Positioning by Counting Rate Variations of a Monitor System

    Corresponding author: CHU Cheng-Sheng,
  • Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, Mianyang621900, China

Abstract: Standard radiative source are monitored by a system containing several detectors. When a source moved out from the monitored area, the counting rates of the system will be changed, and the position and radiation intensity of the source can be estimated by the counting rates variations.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return