MULTI-PROBE MAGNEIC FIELD MEASURING SYSTEM WITH HIGH PRECISION
- Received Date: 1900-01-01
- Accepted Date: 1900-01-01
- Available Online: 1987-06-05
Abstract: HIRFL magnetic field measuring system was built in October, 1983. There are 94 Hall probes on a detecting arm. The positioning device, which mainly consists of a detecting arm, a rotating ring and a fixed ring, is of a polar coordinate type. For 16KG magnetic field, the measuring repeatability of the system is better than ±5×10-5, the measuring accuracy is about ±1×10-4. The measuring rate is about 188 data per minute.