                                 Abstract:A xenon lamp-fibre glass apparatus as a monitor system of counters of Mark-Jdetector has been built. There are 208 channels of fibre to photomultipliers of counters.The calibration of pulse amplitude of counters and the relation of time between coun-ters has been given. Due to the reference tube system, the stability of the apparatus has been improvedand the accuracy of measurement has approached to ±1%. After long time operation, we found that the apparatus are stable and reliabledesirable.
- 
	                          
- 
                        References
	
			| [1] | Mark-1合作组,1980年《中国科学》,专辑“光子、轻子、层子和胶子”. 
 |  
 
- 
                    	
	
				| [1] | HUANG Wen-Xue
								, WANG Yue
								, ZHU Zhi-Chao
								, TIAN Yu-Lin
								, XU Hu-Shan
								, SUN Zhi-Yu
								, XIAO Guo-Qing
								, ZHAN Wen-Long
								. Experimental Study of the High-Voltage Breakdown and Simulations for the RFQ Cooler and Buncher RFQ1L. Chinese Physics C,
							2006, 30(S2): 261-264. |  
				| [2] | ZHOU Yong-Zhao
								, LIANG Hao
								, XUE Jun-Dong
								, CHEN Yi-Xin
								, YANG Tao
								, GONG Da-Tao
								, JIN Ge
								, YU Xiao-Qi
								. An Online Program for Monitoring KLOE Experiment. Chinese Physics C,
							2002, 26(6): 620-625. |  
				| [3] | PENG Quan-Ling
								, SUN Jian
								, ZHAO Guang-Yuan
								, SHI Cai-Tu
								. Principle and Software Design of Helmhotz Coil Measurement System. Chinese Physics C,
							2001, 25(9): 920-925. |  
				| [4] | Xu Jianming
								. Matching Problem of Lattice with Transverse Coupling. Chinese Physics C,
							1995, 19(1): 73-81. |  
				| [5] | WANG Man
								, LI Jin
								, CUI Xiang-Zong
								, XIA Xiao-Mi
								, LAI Yuan-Fen
								, YAO Xiao-Guang
								. PROTOTYPE OF END CAP SHOWER COUNTERAND ITS BEAM TEST. Chinese Physics C,
							1987, 11(3): 321-326. |  
 
- 
                        Access  
- 
                        
-