Study on the Light Output Non-uniformity of PbWO4 Crystal

  • This paper presents the measurement on the light output non uniformity of full size PbWO4 crystal, which will be used in the electromagnetic calorimeter (ECAL) of CMS detector. It makes use of the 22Na radiactive source and the coincident method. With the help of convolution fitting method, it is possible to make fine measurement on the light output non uniformity of the crystal. The effect of depolishing one of the lateral faces of the crystal on the non-uniformity has been studied. The slope of the non uniformity curve decreases with the increasing of the roughness. When the roughness reaches Rz=(1.49±0.27)μm the non uniformity curve meets the requirement of CMS ECAL.
  • 加载中
  • [1] . The CMS Electromagnetic Calorimeter Project Technical Design Report.CERN/LHCC97–33,1997,304—3052. Auffray E,Cavallari F,Davies G J et al.CMS Internal Note CMS,2000,0143. Hillemanns H,Kirn T,Schwenke J et al.CMS NOTE,1998,0054. Depass P,Ernenwein J P,Ille B et al.CMS NOTE,1998,0685. WU J,XU T,LI Ch et al.Nucl.Instr.and Meth.,1998,A419:154—1596. XU Tong,SHAO Ming,LI Cheng et al.Accepted by Nuclear Instrument and Method,Section A,20007. SHAO Ming,LIU HengWen,ZHANG ZiPing.High Energy Phys.and Nucl.Phys.,2001,25(1):50(in Chinese)(邵明,刘衍文,张子平等.高能物理与核物理,2001,25(1):50)
  • 加载中

Get Citation
SHAO Ming, XU Tong, LIU Ming-Chang, WANG Cong-Rong, RUAN Li-Juan, CHEN Hong-Fang, PAN Xiao-Hui and WANG Cong-Zhou. Study on the Light Output Non-uniformity of PbWO4 Crystal[J]. Chinese Physics C, 2001, 25(6): 555-560.
SHAO Ming, XU Tong, LIU Ming-Chang, WANG Cong-Rong, RUAN Li-Juan, CHEN Hong-Fang, PAN Xiao-Hui and WANG Cong-Zhou. Study on the Light Output Non-uniformity of PbWO4 Crystal[J]. Chinese Physics C, 2001, 25(6): 555-560. shu
Milestone
Received: 2000-06-26
Revised: 1900-01-01
Article Metric

Article Views(3910)
PDF Downloads(631)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Study on the Light Output Non-uniformity of PbWO4 Crystal

    Corresponding author: SHAO Ming,
  • SHAO Ming 1 \ XU Tong\ LIU Ming Chang\ WANG Cong Rong RUAN Li Juan\ CHEN Hong Fang Department of Modern Physics, University of Science and Technology of China, Hefei\ 230026, China PAN Xiao Hui\ WANG Cong Zhou College of Mechanical and Auto Engineering, Hefei University of Technology, Hefei\ 230009, China

Abstract: This paper presents the measurement on the light output non uniformity of full size PbWO4 crystal, which will be used in the electromagnetic calorimeter (ECAL) of CMS detector. It makes use of the 22Na radiactive source and the coincident method. With the help of convolution fitting method, it is possible to make fine measurement on the light output non uniformity of the crystal. The effect of depolishing one of the lateral faces of the crystal on the non-uniformity has been studied. The slope of the non uniformity curve decreases with the increasing of the roughness. When the roughness reaches Rz=(1.49±0.27)μm the non uniformity curve meets the requirement of CMS ECAL.