Study on Pores and Defect by Synthrotron Radiation Small Angle Reflection Method and Slow Positron Annihilation Technique

  • We measured the X-ray small angle refection (XRR) in Beijing Synchrotron Radiation facility (BSRF) and the Doppler broaden of positron in Beijing slow positron beam with 22Na radiation source for pore SiOx(1≤x≤1.6) film prepared by radio-frequency sputtering at different Ar pressures.The result of XRR showed that with the Ar pressures increasing,densities of films were decreasing and porosity were increasing.Positron annihilation result S parameters were decreasing with Ar increasing,this contributed to the paramagnetic defect E' center reducing Ps production.Comparing with the thickness of films with XRR method and slow positron annihilation analyzing program VEPFIT,it showed that the results were consistency and the result of VEPFIT was samller.
  • 加载中
  • [1] ZHENC: W et al. J. Appl. Polym. Sci. ,2002,83 : 1862 Koshizaki N , Yasumoto K, Terauchi S. Jpn. J. Appl. Phys. ,1995 ,34(Suppl. 34-1 ) :1193 Kimerling L C et al. Solid State. phys. ,1996,50 :3334 Miller R D. Science, 1999,286 :4215 Asoka-Kumar P, Lynn K G,Welch D 0. J. Appl. Phys. , 1994,76:49356 Petkov M P et al. Appl. Phys. Lett., 2002,79 :38847 SUN J N et al. Appl. Phys. Lett. ,2002,81: 14478 WU Wen-Li et al. Lynn, J. Appl. Phys. ,2000,87(3) :I1939 Eric K. Appl. Phys. Lett. ,2002,81 (4) : 60710 YU R S et al. Jour. Appl. Phys. ,2003,93(6) :334011 Hinds B J et al. Journal of Non-Crystalline Solids,1998,227-230:507-51212 REFSIM Version 1. 2, User ' s Manual, Bruker Analytical X-raySyslems, 199813 Physics Reports 257,223-348 :26614 Mills A P et al. Phys. Rev. , 1982 ,A26 :49015 Vehanen A. Apll. Phys. , 1987, A43 :26916 Lynn K G ,Lutz H. Phys. Rev. ,1980, B22:414317 HE Y J et al. Phys. Rev. ,1986, B33 :5924
  • 加载中

Get Citation
ZHOU Chun-Lan, WANG Dan-Ni, HE Chuang-Xin, WANG Bao-Yi, WEI Long, HE Qing and JIA Quan-Jie. Study on Pores and Defect by Synthrotron Radiation Small Angle Reflection Method and Slow Positron Annihilation Technique[J]. Chinese Physics C, 2003, 27(S1): 67-71.
ZHOU Chun-Lan, WANG Dan-Ni, HE Chuang-Xin, WANG Bao-Yi, WEI Long, HE Qing and JIA Quan-Jie. Study on Pores and Defect by Synthrotron Radiation Small Angle Reflection Method and Slow Positron Annihilation Technique[J]. Chinese Physics C, 2003, 27(S1): 67-71. shu
Milestone
Received: 2003-11-21
Revised: 1900-01-01
Article Metric

Article Views(3279)
PDF Downloads(596)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Study on Pores and Defect by Synthrotron Radiation Small Angle Reflection Method and Slow Positron Annihilation Technique

    Corresponding author: ZHOU Chun-Lan,
  • Institute of High Energy Physics,CAS,Beijing 100039,China

Abstract: We measured the X-ray small angle refection (XRR) in Beijing Synchrotron Radiation facility (BSRF) and the Doppler broaden of positron in Beijing slow positron beam with 22Na radiation source for pore SiOx(1≤x≤1.6) film prepared by radio-frequency sputtering at different Ar pressures.The result of XRR showed that with the Ar pressures increasing,densities of films were decreasing and porosity were increasing.Positron annihilation result S parameters were decreasing with Ar increasing,this contributed to the paramagnetic defect E' center reducing Ps production.Comparing with the thickness of films with XRR method and slow positron annihilation analyzing program VEPFIT,it showed that the results were consistency and the result of VEPFIT was samller.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return