Study on Beam Spot Size Requirement in PES, BSRF and the Beamline Upgrade

  • Different photoelectron analyzer has different detectable area and acceptance angle, the experimental count rate is up to the photon flux density in the detected area, so the size of the X-ray source used for the analyzer is very important to get the best experimental result. Due to the experimental resolution and count rate of the analyzers is not so ideal, their relation to the beam spot of the beamline is studied. Result shows the size of beam spot at the sample position is too large,which helped to decide the upgrade project for beamline 4B9B and make the beam size much more smaller. A new design for high photon energy branch of the beamline upgrade with new post-focusing mirror is finished, meanwhile the focusing of low photon energy branch is also better designed.
  • 加载中
  • [1] . VSW Scientific Instruments Corporation. VSW InstructionManual on HA150, HA54 Hemispherical Analyzer, 19892. CHEN C T, Plummer E W. Nucl. Instrum. Methods, 1984,222: 1033. Edited by Institute of High Energy Physics. Research Re-port of Beijing Synchrotron Radiation Facility, NationalLaboratory of Beijing Electron Positron Collider, 1992.1(in Chinese)(中科院高能物理研究所编辑.北京同步辐射装置研制报告,北京正负电子对撞机国家实验室,1992.1)4. SHU D, WANG W, LIU W et al. Rev. Sci. Instrum., 1989,60(7): 20855. YAN Yong-Lian, LIU Feng-Qin, YANG Yi et al. Improve-ment of Toroidal Mirror in Beamline 4B9B, In: AnnualReport of BSRF, 1993, 26,(in Chinese)(阎永廉,刘风琴,杨易等.4B9b束线超环面镜的改进.见:北京同步辐射装置年报1993, 26)6. QIAN Hai-Jie, YAN Yong-Lian et al. HEP NP, 2004,28(3): 321(in Chinese)(钱海杰,阎永廉等.高能物理与核物理,2004, 28(3): 321)
  • 加载中

Get Citation
QIAN Hai-Jie, YAN Yong-Lian, SU Run and WANG Jia-Ou. Study on Beam Spot Size Requirement in PES, BSRF and the Beamline Upgrade[J]. Chinese Physics C, 2005, 29(S1): 144-147.
QIAN Hai-Jie, YAN Yong-Lian, SU Run and WANG Jia-Ou. Study on Beam Spot Size Requirement in PES, BSRF and the Beamline Upgrade[J]. Chinese Physics C, 2005, 29(S1): 144-147. shu
Milestone
Received: 2005-10-31
Revised: 1900-01-01
Article Metric

Article Views(3330)
PDF Downloads(610)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Study on Beam Spot Size Requirement in PES, BSRF and the Beamline Upgrade

    Corresponding author: QIAN Hai-Jie,
  • Institute of High Energy Physics,CAS,Beijing 100049,China

Abstract: Different photoelectron analyzer has different detectable area and acceptance angle, the experimental count rate is up to the photon flux density in the detected area, so the size of the X-ray source used for the analyzer is very important to get the best experimental result. Due to the experimental resolution and count rate of the analyzers is not so ideal, their relation to the beam spot of the beamline is studied. Result shows the size of beam spot at the sample position is too large,which helped to decide the upgrade project for beamline 4B9B and make the beam size much more smaller. A new design for high photon energy branch of the beamline upgrade with new post-focusing mirror is finished, meanwhile the focusing of low photon energy branch is also better designed.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return