Design of An Electron Linear Accelerator Applied for Sterilizing Anthrax-bacilus in Mails

  • In the paper, design of a 2MeV electron linac is introduced, which includes calculation about parameters of the accelerator structure, longitudinal and transverse dynamics. This linac is used for sterilizing anthrax-bacilus in mails. Machine test shows that parameters of the accelerator can satisfy the design target.
  • 加载中
  • [1] . Helmut Wiedemann. Particle Accelerator Physics.Springer-verlag Berlin Heidelberg New York,1999. 25—492. David H. Whittum. Introduction to Electrodynamics Mi-crowave Linear Accelerators, Beijing: China AcceleratorPhysice School 1998(CAPS98) held at China Center of Ad-vanced Science and Technology, 1998. 77—79, 81—843. Thomas P.Wangler. Principles of RF Linear Accelerators,Published in Canada, 1998. 78-80, 218—2194. YAO Chong-Guo. Electron Linear Accelerator. Beijing:Science Publisher, 1986(in Chinese)(姚充国.电广直线加速器.北京:科学出版社,1986)
  • 加载中

Get Citation
FENG Guang-Yao, PEI Yuan-Ji and Sun Hong-Bing. Design of An Electron Linear Accelerator Applied for Sterilizing Anthrax-bacilus in Mails[J]. Chinese Physics C, 2006, 30(S1): 120-122.
FENG Guang-Yao, PEI Yuan-Ji and Sun Hong-Bing. Design of An Electron Linear Accelerator Applied for Sterilizing Anthrax-bacilus in Mails[J]. Chinese Physics C, 2006, 30(S1): 120-122. shu
Milestone
Received: 2005-12-07
Revised: 1900-01-01
Article Metric

Article Views(4974)
PDF Downloads(606)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Design of An Electron Linear Accelerator Applied for Sterilizing Anthrax-bacilus in Mails

    Corresponding author: FENG Guang-Yao,
  • National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230029, China

Abstract: In the paper, design of a 2MeV electron linac is introduced, which includes calculation about parameters of the accelerator structure, longitudinal and transverse dynamics. This linac is used for sterilizing anthrax-bacilus in mails. Machine test shows that parameters of the accelerator can satisfy the design target.