Calibration and Error Calculation for the Newly BPM System in HLS

  • A vertical calibration system with the error of about ±15μm for the newly eight BPMs is described here, which has been developed for the upgrade of the injection system in NSRL phase II project. A data procession to calibrate the BPM and the error calculation methods for fitting of the electric field as well as the calculating result are also presented. A commercial available Bergoz BPM Module, which works on heterodyne receiving with up tp 75dB dynamic range and 1μm resolution, is introduced. With the calibration system and the data procession methods, we have completed the calibration and the inspection of the quality for newly developing eight BPMs.
  • 加载中
  • [1] . WANG JunHua,YIN Yang et al.A Closed Orbit Measurement with the NSRL BPM System.Proceedings of the18th PAC(PAC 99),NewYork1999May,2048—2050 2. SHEN GLianGuan,WANG JunHua et al.Development of Measurement Equipment for Calibrating Beam Position Monitorin HLS Storage Ring,Proceedings of the19th PAC(PAC2001),Chicago USA 2001July 3. WANG JunHua,LIU JianHong et al.High Power Laser and Particle Beams,2001,6:560—564(in Chinese)(王筠华,刘建宏等,强激光与粒子束,2001,6:560—564)
  • 加载中

Get Citation
WANG Jun-Hua, SHEN Lian-Guan, WANG Gui-Cheng and LIU Jian-Hong. Calibration and Error Calculation for the Newly BPM System in HLS[J]. Chinese Physics C, 2001, 25(11): 1120-1127.
WANG Jun-Hua, SHEN Lian-Guan, WANG Gui-Cheng and LIU Jian-Hong. Calibration and Error Calculation for the Newly BPM System in HLS[J]. Chinese Physics C, 2001, 25(11): 1120-1127. shu
Milestone
Received: 2000-12-25
Revised: 1900-01-01
Article Metric

Article Views(3884)
PDF Downloads(618)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Calibration and Error Calculation for the Newly BPM System in HLS

    Corresponding author: WANG Jun-Hua,
  • National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230029, China

Abstract: A vertical calibration system with the error of about ±15μm for the newly eight BPMs is described here, which has been developed for the upgrade of the injection system in NSRL phase II project. A data procession to calibrate the BPM and the error calculation methods for fitting of the electric field as well as the calculating result are also presented. A commercial available Bergoz BPM Module, which works on heterodyne receiving with up tp 75dB dynamic range and 1μm resolution, is introduced. With the calibration system and the data procession methods, we have completed the calibration and the inspection of the quality for newly developing eight BPMs.