Abstract:
The adjustment of the mean axial electric field in the 10 MeV cavity of Beijing Proton Linac is described. The comparsion of the adjusting fesults with those of some foreign proton linacs is presented. It is demonstrated that adjusting result of the mean axial electric field is satisfactory in the beam transmissive experiment of the 10 MeV cavity.
-
-
References
[1]
|
Shu-Hung Waug, Tzu-Hua Lo, Pi-Jin Chang a d Ping-Hsong Lo, Design study of the Beijing 200MeV Proton Linac, Proc. of the 1979 Linear Accelerator Conf., p. 5.[2] V. G. Eul'man, V. M. Pirozhenko and V. B. Chistov, Tuning of the cavities of a proton linear acclerator, Soviet Conference on Charge-particle Accelerators, Moseow, 9-16 October Vol. 2 1968,86.[3] 沈致远主编“微波技术”国防工业出版社,1980年,第240页.[4] P. M. Lapostolle, Linear Accelerators, North-Holland Publishing Company-Amsterdam, p. 593.[5] G. Pazen. Perturbation and tolerances in a 200 MeV Proton Kim, Boc. of the Sixth high energy Heeelerator national conference PA-34, 1967.[6] Jiro Tanaka, etc., Synchrnous phase law experernent in the EEK Linac, KEK-77-3 May 1977.[7] C. D. Curtis, etc., The operation of the first section of the NAL Linear Accelerator, Particle Aeeelerators,Vol. 1 1970. 93.[8] D. A. Swenson, Operation of the first Tank of LAMPF, Proc. of 1970 Proton Linear Accelerator Conf.P. 175.
|
-
-
Access
-
-