ADJUSTMENT OF THE MEAN AXIAL ELECTRIC FIELD IN THE 10 MEV ACCELERATING CAVITY

  • The adjustment of the mean axial electric field in the 10 MeV cavity of Beijing Proton Linac is described. The comparsion of the adjusting fesults with those of some foreign proton linacs is presented. It is demonstrated that adjusting result of the mean axial electric field is satisfactory in the beam transmissive experiment of the 10 MeV cavity.
  • 加载中
  • [1] Shu-Hung Waug, Tzu-Hua Lo, Pi-Jin Chang a d Ping-Hsong Lo, Design study of the Beijing 200MeV Proton Linac, Proc. of the 1979 Linear Accelerator Conf., p. 5.[2] V. G. Eul'man, V. M. Pirozhenko and V. B. Chistov, Tuning of the cavities of a proton linear acclerator, Soviet Conference on Charge-particle Accelerators, Moseow, 9-16 October Vol. 2 1968,86.[3] 沈致远主编“微波技术”国防工业出版社,1980年,第240页.[4] P. M. Lapostolle, Linear Accelerators, North-Holland Publishing Company-Amsterdam, p. 593.[5] G. Pazen. Perturbation and tolerances in a 200 MeV Proton Kim, Boc. of the Sixth high energy Heeelerator national conference PA-34, 1967.[6] Jiro Tanaka, etc., Synchrnous phase law experernent in the EEK Linac, KEK-77-3 May 1977.[7] C. D. Curtis, etc., The operation of the first section of the NAL Linear Accelerator, Particle Aeeelerators,Vol. 1 1970. 93.[8] D. A. Swenson, Operation of the first Tank of LAMPF, Proc. of 1970 Proton Linear Accelerator Conf.P. 175.
  • 加载中

Get Citation
LUO Zi-Hua and WANG Shu-Hong. ADJUSTMENT OF THE MEAN AXIAL ELECTRIC FIELD IN THE 10 MEV ACCELERATING CAVITY[J]. Chinese Physics C, 1984, 8(2): 185-190.
LUO Zi-Hua and WANG Shu-Hong. ADJUSTMENT OF THE MEAN AXIAL ELECTRIC FIELD IN THE 10 MEV ACCELERATING CAVITY[J]. Chinese Physics C, 1984, 8(2): 185-190. shu
Milestone
Received: 1900-01-01
Revised: 1900-01-01
Article Metric

Article Views(2872)
PDF Downloads(494)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

ADJUSTMENT OF THE MEAN AXIAL ELECTRIC FIELD IN THE 10 MEV ACCELERATING CAVITY

    Corresponding author: LUO Zi-Hua,

Abstract: The adjustment of the mean axial electric field in the 10 MeV cavity of Beijing Proton Linac is described. The comparsion of the adjusting fesults with those of some foreign proton linacs is presented. It is demonstrated that adjusting result of the mean axial electric field is satisfactory in the beam transmissive experiment of the 10 MeV cavity.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return