Design Study on a 10 MeV Proton Isochronous Cyclotron
- Received Date: 2005-01-24
- Accepted Date: 1900-01-01
- Available Online: 2005-10-05
Abstract: The design of the isochronous magnet field and central region for 10MeV proton isochronous cyclotron has been studied. There is only one set of exciting coil, and the isochronous magnet field is mainly determined by the shape of magnet pole. The designed central region provides an enough large acceptance at the exit of PIG source for having a large beam current. The centering of the orbits is also permitted. The beam qualities are presented after 172 turn acceleration with the beam energy of 10MeV. The proton beam delivered by this cyclotron can be used in Positron Emission Tomography(PET) and so on.





Abstract
HTML
Reference
Related
PDF












DownLoad: